Schedule 7 Articles of glazed ceramic ware, methods of testing and permissible levels of metal release
(regulation 4E)
Column
1
Column
2
Column
3
Column
4
Column
5
Item
Description
of Article
Method
of testing
Amount
of lead per volume of solution
Amount
of cadmium per volume of solution
milligrams
per litre
milligrams
per litre
1
Cup,
mug, jug, jar, bowl, teapot, coffee pot or other article of tableware (other
than an article referred to in Item 3) having a liquid capacity of less than
1100 millilitres.
Method
specified and described
in paragraph 4 (other
than
sub-paragraph 4.1) of Part 1 of British Standard 4860 published on
31 October 1972.
7.0
0.7
2
Cup,
mug, jug, jar, bowl, teapot, coffee pot or other article of tableware (other
than an article referred to in Item 3) having a liquid capacity equal to or in
excess of 1100 millilitres.
Method
specified and described
in paragraph 4 (other than
sub-paragraph 4.1) of
Part 1 of British Standard 4860 published on 31 October 1972.
2.0
0.2
3
Plate
(including soup plate or dessert plate), saucer, or similar article of tableware.
Method
specified and described
in paragraph 4 (other than
sub-paragraph 4.1) of
Part 1 of British Standard 4860 published on 31 October 1972.
20.0
2.0
4
Any
article of cooking ware.
Method
specified and described
in paragraph 4 (other than
sub-paragraph 4.1) of
Part 2 of British Standard 4860 published on 31 October 1972.
7.0
0.7